Smart-power-systems ER Series Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Générateurs Smart-power-systems ER Series. Smart Power Systems ER Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
A.C. MODULAR
GENERATOR SYSTEM
OWNERS MANUAL
MODEL#: ER-6.2, ER-8, ER-10 and ER-110
For Compartment or Top Mounting
Vue de la page 0
1 2 3 4 5 6 ... 52 53

Résumé du contenu

Page 1

A.C. MODULAR GENERATOR SYSTEM OWNERS MANUAL MODEL#: ER-6.2, ER-8, ER-10 and ER-110 For Compartment or Top Mounting

Page 2

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 9 of 52 Figure 2 System Specifications MODEL OF GENERATOR ER-6.2 ER-8 ER-10 ER-110 Generato

Page 3

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 10 of 52 Table 1 MODEL OF GENERATOR ER-6.2, ER-8 ER-10, ER-110 Oil Cooler Dimensions

Page 4

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 11 of 52 Pre-Installation Guide Pre-Installation Check List 1. Verify that the Power Tak

Page 5

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 12 of 52 3. Verify the combined weight of the pump and hoses filled with hydraulic fluid do

Page 6

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 13 of 52 WARNING: Do not install hose ends until proper hose length has been determined.

Page 7

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 14 of 52 12" MINIMUM OBSTRUCTIONFREE CLEARANCEOIL FILTERACCESS PANEL Front view of ER-

Page 8

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 15 of 52 WARNING: Do not mount the hydraulic pump or tray assembly in any location that is

Page 9 - WINDING B

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 16 of 52 Installation Guide 1. Mount the pump securely to the Power Take-Off (PTO). This

Page 10

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 17 of 52 3. Mount the tray assembly as high as possible within the structure of the vehicle

Page 11

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 18 of 52 .208CLEARANCE HOLEFOR #10 SCREW4 PL.2.0003.3753.3751.6881.688 Hole pattern for Comm

Page 12

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 1 of 52 Table of Contents Section Page Disclaimer ...

Page 13

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 19 of 52 Use caution when tightening the hose ends to prevent the hose from becoming twisted

Page 14

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 20 of 52 ALTERNATE CONFIGURATION: 120 VAC only: If the application requires 120 VAC only, th

Page 15 - FREE CLEARANCE

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 21 of 52 the system’s warranty. Replacement breakers must be obtained from Smart Power® Sys

Page 16 - 1.375 .45

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 22 of 52 Note: The generator is shipped from the factory with the purge option enabled. T

Page 17

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 23 of 52 Enabling System Purge Option The purge option can also be set by performing the fo

Page 18

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 24 of 52 g. Check for hydraulic fluid leaks, all hose connections must be tight. Monitor t

Page 19

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 25 of 52 Step b: Hold Mode until Amps Line 1 Blinks 88. Release switch so 0Pt and AStr ap

Page 20

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 26 of 52 Operation 1. The Command & Control Center will show the generator’s output vo

Page 21

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 27 of 52 Normally, the status lights will be off. When a switch is pressed, the correspondi

Page 22

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 28 of 52 Displayed Oil Temperature in degrees Fahrenheit Example of oil temperature displ

Page 23

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 2 of 52 WARNING: Do not install or operate the A.C. modular generator system without readi

Page 24

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 29 of 52 The system controller is configured to operate a generator whose maximum output is

Page 25

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 30 of 52 a. From the Normal mode display, press Mode, as if you wanted to display the oil t

Page 26

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 31 of 52 Step a: Press Mode to cause rvn and the y and n labels to appear. Step b: Press On/

Page 27 - On/Off Switch Status Light

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 32 of 52 Special Operating Instructions Cold Weather Procedure: It is strongly recommende

Page 28

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 33 of 52 Maintenance Instructions WARNING: Do not perform maintenance while system is ru

Page 29 - Change in Hours

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 34 of 52 Lubricate the oil filter gasket with Dexron III before installation to permit prop

Page 30

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 35 of 52 Step a: Press Mode until InF, 0IL, and FILt appear. Step b: Hold Mode switch down

Page 31 - Step c: Press On/Off to

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 36 of 52 Troubleshooting Guide Diagnostic: The Command & Control Center will display c

Page 32

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 37 of 52 Diagnostic Faults: The following is a list of the diagnostic faults, with a brief

Page 33

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 38 of 52 Hydraulic Problems: 1. Cavitation: Cavitation is caused by trying to pump more f

Page 34

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 3 of 52 Never operate the system with leaks of any type. Clean up any hydraulic fluid that

Page 35

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 39 of 52 3. Differential Pressure: Differential pressure between the inlet pressure and th

Page 36

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 40 of 52 a. Check the oil cooler fins for debris or damage. Clean and/or replace cooler.

Page 37

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 41 of 52 d. The stator field may be shorted or open. With a flashlight, check the generator

Page 38 - Class Meaning

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 42 of 52 h. The pump is faulty. If no faults are found in steps a. through g., the problem

Page 39

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 43 of 52 SPS Model Matrix PARENT P/N DESCRIPTION TRAY ASM P/N PUMP ASM P/N RANGE

Page 40

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 44 of 52 Component Part Number Lists (Reference Figure 27 and Figure 28) ITEM NO. 1 2 3 4 5

Page 41

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 45 of 52 ER-6.2, ER-8, ER-10 AND ER-110 Assembly drawing Figure 27

Page 42

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 46 of 52 2LID LATCH(2 EA) 194THIS VIEW SHOWN WITH LID REMOVED11381510125147 ER-8, ER-10 an

Page 43

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 47 of 52 Pump Adjustment WARNING: The SPS Electronic Controlled Generators have been pre

Page 44

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 48 of 52 The Pump Set option can be accessed by performing the following steps: Step b:

Page 45

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 4 of 52 Operating the A.C. modular generator system in the presence of flammable vapors may

Page 46

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 49 of 52 2. Adjust pump compensator: a. Loosen and remove flow control cap. Referenc

Page 47 - LID LATCH

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 50 of 52 3. Disable the generator Pump Set option. After the pump has been properly adju

Page 48

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 51 of 52 Manufacturers Limited Warranty Smart Power® Systems Hydraulic Generator Coverage

Page 49

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 52 of 52 5. The cost of airfreight or other extraordinary expenses for shipment of parts o

Page 50

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 5 of 52 Disclaimer Although SPS has taken all reasonable care to ensure that the informat

Page 51

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 6 of 52 Description of Product Hydraulic Generator Applications: This heavy-duty electroni

Page 52

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 7 of 52 CASE DRAINxyRESERVOIRPUMPPROPORTIONALVALVECASE DRAINMOTORCOOLERFILTERBOOST BLOCKVEN

Page 53

Smart Power® Systems A. C. MODULAR GENERATOR SYSTEM Page 8 of 52 +-Fan Motor221121CONN 5CONN 6323211REMOTE ENB. SW (MUST BEA MOMENTARY SWITCH)BUZZER4

Commentaires sur ces manuels